Datamax-oneil DPL Programmer’s Manual Bedienungsanleitung Seite 116

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 296
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 115
Extended System-Level Command Functions
108
STX KuW Write Data to RFID Tag
(Direct Mode – UHF Interface – Hexadecimal Data Only)
This command instructs the RFID device to write data to the tag. It is expected that the
tag transponder will be within the read / write distance of the RFID programming device;
otherwise, a warning will occur and a warning message (Read / Write Fail) will be
displayed.
Syntax:
<
STX>KuW
bcc…
<
CR
>
Where:
a
-
The number of attempts to locate, erase and program
the tag (1 – 9).
b
-
Reserved. Should be 0.
cc…c
-
Data to be encoded in the ASCII format. Must be
sixteen characters in length. The valid characters are
0-9, A-F.
Must be 16 or 24 characters long.
Sample:
<STX>KuW10ABCDEF0102030405[CR]
The sample above programs the data
<0xAB><0xCD><0xEF><0x01><0x02><0x03><0x04><0x05> to the
tag, attempting to write one additional time if necessary.
STX KV Verifier Enable/Disable
This command allows a verifier to be enabled and disabled.
Syntax:
<
STX>KVa
<
CR
>
Where:
a
-
Y = verifier enable
N = verifier disable
This command will result in a system reset for the EX2.
Seitenansicht 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 295 296

Kommentare zu diesen Handbüchern

Keine Kommentare