Extended System-Level Command Functions
62
Value Interpretation
Input Mode Interpretation
8 PL-E
9 Auto
Character strings are automatically parsed and processed
according to the identified language.
A clean file is required, where extra leading characters
may cause the language to be unrecognizable;
otherwise, the appropriate Input Mode must be
selected.
10 CPCL
11 O’Neil EZ Print
(EN) End Character – This command terminates a <STX>Kc string.
(EP) End of Print – This command defines the signal output used to signify the End
of Print (EOP) process:
Value Units End of Print Interpretation
1 Low Pulse
Outputs a low pulse (approximately 30 milliseconds long)
following printing.
2 High Pulse
Outputs a high pulse (approximately 30 milliseconds long)
following printing.
3 Active Low Outputs a logic low (zero) following printing.
4 Active High Outputs a logic high (one) following printing.