Seitenansicht 77
69
b.
General
Select General to enable or disable the appropriate settings:
Page Format Shading - Used for diagnosing label format issues, enabling this option puts
a shade over white areas of the image on a label.
File Capture Used for capturing print data for diagnosics. Print files will be generated
using a time stamp for the name. These files will be placed in the user labels internal
directory. If a USB memory stick is inserted, the files will be saved to /users_labels.
Test Options
The Test Options function of the Diagnostics menu allows the user to test the options currently installed
on the printer. Select Test Options and navigate through the tabbed interface to select the option to be
tested. The tabs are navigated using the next and previous arrows in the taskbar.
Test Options
Values
Ranges
Default
Cycle Cutter
1 to 999
1
Test Present Sensor
N/A
Test Rewinder
N/A
Test Ribbon Assembly
N/A
Once the selections have been made, select the Start button to begin the test.
Test GPIO
The Test GPIO function allows the user to test a connected applicator.
Selections
Values
Ranges
Default
Enable Wrap Around
Enabled
Disabled
Disabled
Pulse Width
1 to 2,000
1,000
I/O Configuration
Sig 1/2
Input
Output
Input
Sig 3/4
Input
Output
Input